1. Product introduction
Jinggu camera desktop lifter prefers motor braking, integrated box body design is stylish and beautiful, stable and quiet operation, convenient installation, simple operation, heavy load, support central control remote control and wire control, and can be directly connected to various central control systems to achieve concentration It can also be remotely controlled separately or controlled by a wire switch. It is widely used in video conference systems, video conference systems, star hotels, corporate conference rooms, conference rooms in government agencies, and other places.
2. Features
1. Double door design, electric control, stylish and beautiful;
2. Optimizing precision motor braking, stable operation without noise, and three-year warranty service;
3. The metal cold-rolled steel paint case panel is matched with all-aluminum lifting rods, which is of high-end atmosphere;
4. One-piece box body design, perfectly hidden inside the table, the table top is neat and beautiful, saving space;
5. Reserved wiring holes, easy to install and operate;
6. Support central control RS232/RS485, wireless radio frequency remote control, wire control button switch, multiple control methods do not interfere with each other;
3. Technical parameters
Model specification: JG700-S
Panel size: 435*398*2.5mm
Box size: 405*370*700mm
Suitable for cameras: ≤260*260*200mm
Lifting height: 310-700mm
Panel color: the panel is black, the lifting rod is silver gray (the panel color can be customized)
Control method: central control RS485/232, wireless radio frequency remote control and wire control key switch
Product weight: 37kg
Motor power: 20W
Power supply: 220V 50HZ alternating current
Accessories list: warranty card, certificate, manual, power cord, manual switch and remote control
4, matters needing attention
1. No water seepage or percussion is allowed;
2. It should not be installed outdoors or on the ground;
3. Input voltage: the power supply voltage must be grounded at 220V (±10%);
4. It is forbidden to put heavy objects on the flip cover;
5. It is forbidden to put the product upside down, pay attention to moisture;
5, product icon
1. Product size drawing:
2. Installation method:
The first step: Put the lifter from top to bottom into the pre-opened hole
Step 2: Make the elevator panel and the desktop level and then power on test
Six, control methods
1. Central control
①RS232 connection line
Use RS232 crossover cable (2-3-5 to 3-2-5) to connect the first projector lifter to the central control 232 serial port;
Each projector lifter can be connected in series with RS232 direct connection (2-3-5 to 2-3-5).
②RS232 port settings:
Baud rate 2400
Data length 8
Parity check N
Stop bit 1
③Centralized control code:
When the machine leaves the factory, there is a default hexadecimal code that can control all ups and downs:
FF 10 11 00 DD all up
FF 10 11 00 EE all down
FF 10 11 00 CC all stop
④ Marshalling control method:
In addition to the default control code, the machine can also log in new codes. However, it is recommended that no more than 3 codes are allowed for each machine. The login code steps are as follows:
5, set the 232 serial port according to the above settings.
Then, connect the line according to the above wiring method.
Secondly, fill in the hexadecimal code (learning code) in the serial port control software: FF 10 11 01 AA FF 10 11 01 AA FF 10 11 01 AA FF 10 11 01 AA; (where 01 means the machine is defined as number 01, if There are multiple machines that can be defined as 02 or 03, etc. However, if multiple machines learn the same code, it means that multiple machines are defined as the same group and will rise and fall at the same time.) -----! ! ! Don't send it after the code is filled out.
Finally, press and hold the "function key" on the projector's elevator panel for about 1 second, and the red indicator light of the elevator will start to flash slowly. Immediately release the button and send the code in the serial port control software, the indicator light will receive the code and stop flashing, the code login is successful.
⑤Control code:
After the code is logged in, the machine can be controlled with 232 code. The control code is as follows:
FF 10 11 01 DD Increase;
FF 10 11 01 EE Decrease;
FF 10 11 01 CC Stop;
⑥Code clear:
Press and hold the "function key" on the projector's elevator panel until the red indicator light on the elevator flashes from slow to fast, release the button when it flashes quickly, and then immediately press the "function key" again. All the codes after login will be cleared. (The original factory code of the machine will not be cleared)
2. Remote control
① Single wireless remote control, one to one control.
②Wireless remote control grouping control, up to five groups, multiple machines grouping, one remote control control operation method.
When the power is turned on, press and hold the "function button" on the elevator panel for about 2 seconds, the indicator light next to it will start to flash, and then press the code matching button on the back of the remote control for about 1 second, the indicator light stops flashing. Then the code is successful. The machine can be controlled with the remote control. Repeat the above operation if unsuccessful.
7, troubleshooting
1. When the devices with multiple control methods are not operating, confirm whether the power cord of the device is normal, confirm whether the fuse is intact, observe whether the indicator light on the circuit board is on, and if there is no problem, contact a technician to solve it;
2. If a certain control method fails, you need to contact the technical staff for telephone or video guidance to re-encode and control. If the problem has not been solved, contact the sales and follow the product warranty after-sales process;
3. Don't panic when there is a foreign object stuck in the equipment, immediately press the stop button or cut off the power to let the equipment stop ordering, then take out the foreign object, and complete the lifting again;
4. When the flip door is lower than the entire panel, put the device on its side to find the red lower limit switch at the bottom, and twist the screw on the opposite side of the limit switch higher;
5. For other uncertain failures, please contact sales to provide professional and technical personnel for guidance.